Remote Dissolved Oxygen Controllers

£1,200.00

πŸ‡¬πŸ‡§Β British-Built | Our own unique design, built by us, in the UK.
βœ… Hourly DO Readings | Dissolved oxygen readings sent to your account once per hour.
πŸ“± SMS Alerts | Instant alerts for low dissolved oxygen levels.
βš™οΈ Customisable Relay | Control aeration equipment automatically.
🚫 No Subscription Fees* | No monthly service subscription.
🌐 IoT Compatibility | Use with our website or other IoT platforms – your choice.
πŸ’΅ Cheapest on the Market | Half the price of our nearest competitors!**

Description

Important Notice(s): We’re experiencing high demand for these units, they are slowly being rolled out with constant software updates and new features being added as we go, meaning we are operating a waiting list.

Please register your interest in the form below to outline your exact requirements so we can best address your enquiry.Β 

Remote Waiting List
First
Last
Site Address/Location
Site Address/Location
Postcode
City
Country

πŸ‡¬πŸ‡§Β British-Built |Β Our own unique design, built by us, in the UK.

βœ… Hourly DO Readings | Dissolved oxygen readings sent to your account once per hour.

πŸ“± SMS Alerts | Instant alerts for low dissolved oxygen levels.

βš™οΈ Customisable Relay | Control aeration equipment automatically.

🚫 No Subscription Fees* | No monthly service subscription.

🌐 IoT Compatibility | Use with our website or other IoT platforms – your choice.

πŸ’΅ Cheapest on the Market | Less than Half the price of our nearest competitors!

See example data from a live unit below.

(Note: this is the last 3 days for demonstration purposes only, full data review and sorting is available on the full product).

Water Temperature (Β°C)

Avg: 6.9Β  Β  Min:Β 6.8 Β  Β Max: 7.2 Β  Β Range: +/- 0.4


Dissolved Oxygen (Mg/L)

Avg: 8.3 Β  Β Min:Β 7.8 Β  Β Max: 8.9 Β  Range: +/- 1.1


Β 

Dissolved Oxygen (% Saturation)

Avg: 69.1 Β  Β Min: 64.7 Β  Β Max: 74.7 Β  Range: +/- 10.0


Β 

Aeration Activity


System Input Voltage

Avg: 12VΒ  Β  Min: 11.9VΒ  Β  Max: 12VΒ  Β  Range:Β +/- 0.1V


Β 

VariablesExternal Control

03:42 on 22/01/26

DO: 8.9Mg/L (74.7%)
Temp: 7.2Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

02:41 on 22/01/26

DO: 8.9Mg/L (74.7%)
Temp: 7.2Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

01:42 on 22/01/26

DO: 8.9Mg/L (74.5%)
Temp: 7.2Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

01:41 on 22/01/26

DO: 8.9Mg/L (74.5%)
Temp: 7.2Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

00:42 on 22/01/26

DO: 8.9Mg/L (74.7%)
Temp: 7.2Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

00:41 on 22/01/26

DO: 8.9Mg/L (74.7%)
Temp: 7.2Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

23:42 on 21/01/26

DO: 8.9Mg/L (74.5%)
Temp: 7.1Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

23:41 on 21/01/26

DO: 8.9Mg/L (74.5%)
Temp: 7.1Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

22:42 on 21/01/26

DO: 8.9Mg/L (74.4%)
Temp: 7.1Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

22:41 on 21/01/26

DO: 8.9Mg/L (74.4%)
Temp: 7.1Β°C

SMS Alarm:
3.5 Mg/L
Relay Status:
On at: 4.0Mg/L, Off at: 4.5Mg/L
(Currently: Off)

 

 

 

 

 

 

Remote Dissolved Oxygen Controllers
£1,200.00